Measurement campaign on the Eider 09/2020
As part of a measurement campaign in September 2020, mobile ADCP flow measurements were carried out in the vicinity of the Eider barrage. For the first time, measurements were... -
ADCP ground anchor station WA 1
Ground anchor with ADCP measurement (flow, turbidity). Two time series with delta t = 5 minutes. NHN depth: 13 m. The anchored ADCP records a complete vertical velocity profile:... -
ADCP ground anchor station WAW 2
Ground anchor with ADCP measurement (current, turbidity, sea state). A time series with delta t = 20 minutes. NHN depth: 15 m. The anchored ADCP records a complete vertical... -
CTD ground anchor station WW 1
Ground anchor with CTD measurement (salinity, temperature, water level). A time series with delta t = 5 minutes. NHN depth: 20 m. Note on the measuring interval dt: The CTD... -
CTD-Messketten-Station WWS 2
Measuring chain with CTD measurement (salinity, temperature, water level, turbidity). Two time series with delta t = 5 minutes. Measurements were made at depths of 3 m, 7 m, 12... -
Sediment sampling at the Eider 08/2021
As part of the Zukunft Eider project, around 150 sediment samples were taken in August 2021 in the outer and tidal eider. Samples were collected as surface samples using a Van... -
ADCP Ground Anchor Station EA 3
Ground anchor with ADCP measurement (current, turbidity). Three time series with delta t = 5 minutes. NHN depth: 10 m. The moored ADCP record a complete vertical velocity... -
ADCP ground anchor station EA 4
Ground anchor with ADCP measurement (current, turbidity). A time series with delta t = 5 minutes. NHN depth: 9 m. The moored ADCP record a complete vertical velocity profile: vr... -
CTD ground anchor station EW 1
Ground anchor with CTD measurement (salinity, temperature, water level). Two time series with delta t = 5 minutes. NHN depth: 22 m. Note on the measurement interval dt: The CTD... -
CTD-Messketten-Station EWS 3
Measuring chain with CTD measurement (salinity, temperature, water level, turbidity). A time series with delta t = 5 minutes. It was measured at depths of 5 m, 9 m and 14 m... -
ADCP ground anchor station EAW 1
Ground anchor with ADCP measurement (current, turbidity, sea state). Two time series with delta t = 20 minutes. NHN depth: 27 m. The moored ADCP record a complete vertical... -
CTD ground anchor station EW 4
Ground anchor with CTD measurement (salinity, temperature, water level). Two time series with delta t = 5 minutes. NHN depth: 13 m. Note on the measurement interval dt: The CTD... -
CTD-Messketten-Station EWS 2
Measuring chain with CTD measurement (salinity, temperature, water level, turbidity). Two time series with delta t = 5 minutes. It was measured at depths of 5 m, 14 m, 22 m and... -
Control edge measurements Elbe and Jade/Weser 2012
The BAW (Federal Institute for Hydraulic Engineering) carries out extensive R&D studies (research and development) on climate impact research and the effects of planned...